PQA 60 - 0.60 HP three-phase peripheral impeller electric pump
Flow rate up to 32 l/min (1.92 m³/h). Head up to 40 m. 0.37 Kw (0.50 HP) motor.
It is recommended for pumping clean water without abrasive particles and liquids that are chemically non-aggressive for the materials from which the pump is made.
Built in RYTON with a brass front cover on the impeller, it offers a safe guarantee against the formation of rust and oxidation; for these characteristics it is recommended for use in the industrial sector, for example for cooling, air conditioning, ironing systems, etc.
Installation must be carried out indoors or in any case protected from the elements.
- Motor connection
- THREE-PHASE
- Motor power (HP)
- 0.50
- Suction mouth
- 1/2 "
- Delivery port
- 1/2 "
- Body Pump
- PPS, with ISO 228/1 threaded metal insert inserted in the ports
- Impeller
- Brass
- Number of impellers
- 1
- Motor shaft
- AISI 431 stainless steel
- Check valve
- no
- Degree of protection
- IP 44
- Flow rate min. (l./min.)
- 2
- Max flow (l./min.)
- 32
- Min head (m.)
- 5
- Max head (m.)
- 40
- Employments
- cooling systems
- Liquid temperature max. (° C)
- +90°C
- Motor voltage
- 400 V
- Height (cm)
- 14.5
- Width (cm)
- 19.8
- Depth (cm)
- 11.6
- Weight kg)
- 4.7
- Guarantee
- 2
|
|
|
|
|
Bearings
Pump side motor bearing | 6201 ZZ |
Opposite side motor bearing | 6201 ZZ |
Shaft seal
Type of seal | Single Mechanical Seal |
Pump side model | ST1-12 |
LP diameter | 12 |
Fixed ring LP | Silicon carbide |
Rotating ring LP | Graphite |
LP elastomer | NBR |
Mat
1.0 - Pump Body | Reinforced technopolymer |
2.0 - Cover | Brass CW617N EN 12165 |
2.1 - Seal holder cover | Brass CW617N EN 12165 |
3.0 - Impeller | Brass CW617N EN 12165 |
4.0 - Pump shaft | EN 1.4057 stainless steel (AISI 431) |
6.0 - Motor holder | Aluminum EN-AB 46100 |
6.1 - Engine cover | DX53D EN 10346 galvanized steel |
7.0 - Lantern | Aluminum EN-AB 46100 |
Compare with Similar Products
PQA 60 - 0.60 HP three-phase peripheral impeller electric pumpThis product Flow rate up to 32 l/min (1.92 m³/h). Head up to 40 m. 0.37 Kw (0.50 HP) motor. | PQA 50 - 0.25 HP three-phase peripheral impeller electric pumpFlow rate up to 28 l/min (1.68 m³/h). Head up to 26 m. 0.18 Kw (0.25 HP) motor. | PQA 70 - 0.75 HP three-phase peripheral impeller electric pumpFlow rate up to 45 l/min (2.7 m³/h). Head up to 65 m. 0.55 Kw (0.75 HP) motor. | PQA 72 - 0.75 HP three-phase peripheral impeller electric pumpFlow rate up to 50 l/min (3 m³/h). Head up to 65 m. 0.55 Kw (0.75 HP) motor. | |
---|---|---|---|---|
Motor connection | Motor connection THREE-PHASE | Motor connection THREE-PHASE | Motor connection THREE-PHASE | Motor connection THREE-PHASE |
Motor power (HP) | Motor power (HP) 0.50 | Motor power (HP) 0.25 | Motor power (HP) 0.75 | Motor power (HP) 0.75 |
Absorption at 230V (A) | Absorption at 230V (A) -- | Absorption at 230V (A) 2.0 | Absorption at 230V (A) 4.2 | Absorption at 230V (A) 3.8 |
Absorption at 400V (A) | Absorption at 400V (A) -- | Absorption at 400V (A) 1.15 | Absorption at 400V (A) 2.4 | Absorption at 400V (A) 2.2 |
Suction mouth | Suction mouth 1/2 " | Suction mouth 1/2 " | Suction mouth 1/2 " | Suction mouth 1 " |
Delivery port | Delivery port 1/2 " | Delivery port 1/2 " | Delivery port 1/2 " | Delivery port 1 " |
Body Pump | Body Pump PPS, with ISO 228/1 threaded metal insert inserted in the ports | Body Pump PPS, with ISO 228/1 threaded metal insert inserted in the ports | Body Pump PPS, with ISO 228/1 threaded metal insert inserted in the ports | Body Pump PPS, with ISO 228/1 threaded metal insert inserted in the ports |
Impeller | Impeller Brass | Impeller Brass | Impeller Brass | Impeller Brass |
Number of impellers | Number of impellers 1 | Number of impellers 1 | Number of impellers 1 | Number of impellers 1 |
Motor shaft | Motor shaft AISI 431 stainless steel | Motor shaft AISI 431 stainless steel | Motor shaft AISI 431 stainless steel | Motor shaft AISI 431 stainless steel |
Check valve | Check valve no | Check valve no | Check valve no | Check valve no |
Degree of protection | Degree of protection IP 44 | Degree of protection IP 44 | Degree of protection IP 55 | Degree of protection IP 55 |
Flow rate min. (l./min.) | Flow rate min. (l./min.) 2 | Flow rate min. (l./min.) 2 | Flow rate min. (l./min.) 2 | Flow rate min. (l./min.) 5 |
Max flow (l./min.) | Max flow (l./min.) 32 | Max flow (l./min.) 28 | Max flow (l./min.) 45 | Max flow (l./min.) 50 |
Min head (m.) | Min head (m.) 5 | Min head (m.) 5 | Min head (m.) 8 | Min head (m.) 12 |
Max head (m.) | Max head (m.) 40 | Max head (m.) 26 | Max head (m.) 65 | Max head (m.) 65 |
Employments | Employments cooling systems | Employments cooling systems | Employments cooling systems | Employments cooling systems |
Liquid temperature max. (° C) | Liquid temperature max. (° C) +90°C | Liquid temperature max. (° C) +90°C | Liquid temperature max. (° C) +90°C | Liquid temperature max. (° C) +90°C |
Motor voltage | Motor voltage 400 V | Motor voltage 400 V | Motor voltage 400 V | Motor voltage 400 V |
Height (cm) | Height (cm) 14.5 | Height (cm) 14.5 | Height (cm) 17.9 | Height (cm) 17.9 |
Width (cm) | Width (cm) 19.8 | Width (cm) 19.8 | Width (cm) 26.1 | Width (cm) 26.1 |
Depth (cm) | Depth (cm) 11.6 | Depth (cm) 11.6 | Depth (cm) 13.4 | Depth (cm) 13.4 |
Weight kg) | Weight kg) 4.7 | Weight kg) 4.7 | Weight kg) 9.4 | Weight kg) 9.5 |
Guarantee | Guarantee 2 | Guarantee 2 | Guarantee 2 | Guarantee 2 |