Active Driver Plus M / T 2.2 - 10.5 A single-phase / three-phase
zoom_out_map
chevron_left chevron_right

Active Driver Plus M / T 2.2 - 10.5 A single-phase / three-phase inverter

Inverter for 230 V three-phase pumps up to 3 HP with single-phase power supply

€814.96

€668.00 Tax excluded

Variants:
Active Driver Plus M/T 1 - Inverter monofase/trifase da 4.7 A
Active Driver Plus M/T 2.2 - Inverter monofase/trifase da 10.5 A
(5/5) out of 1 total ratings
Read the reviews
Close
Make a purchase proposal

Your Offer is sent.

Your Offer is accepted, please check your inbox.

Active Driver Plus M / T 2.2 - 10.5 A single-phase / three-phase inverter
  • Use dot instead of comma

Loading

Telephone support for information before purchasing.
After-sales assistance for product installation.
Description

Active Driver Plus M / T 2.2 is an inverter for the control and command of single-phase hydraulic pumps and finds its natural application in both domestic, industrial and agricultural constant pressure pumping systems.

Innovative thanks to dual processor technology and extremely compact, Active Driver Plus M / T 2.2 ensures a new ease of installation thanks to the simple wizard.

It ensures the highest levels of comfort thanks to the constant pressure. Constant pressure is achieved by controlling the speed of the pump and running it at minimum speed, which ensures the required pressure and flow. This ensures a significant reduction in energy consumption, noise and extension of the pump's life.

The Active Driver starts the pump at the first request for water.

The pump speed is adjusted (continuously) to the minimum value such as to satisfy the demand of the user. This allows for significant energy savings. If installed in a group, the start-up of the second and third pumps occurs in cascade, when the first pump reaches the maximum rotation speed.

The pressure can be adjusted by the user by means of two + and - keys placed on Active Driver (as a rule all pumps are set to the same pressure value).

The pumps are automatically stopped in the following cases:
- Pump overcurrent
- Dry running
- Low power supply voltage
- Exceeding a maximum pressure value (adjustable)
- Active Driver Plus electronic components overheating.

Data sheet
DAB
60170687
20 Items
Suction mouth
1 "1/4
Delivery port
1 "1/2
Degree of protection
IP 55
Max flow (l./min.)
300
Line power supply
single phase
Supply voltage (Volt)
230
Line current
22
Line phases
3 x 230 V
Motor power supply
three-phase
Motor voltage
230 V
Engine phases
3 x 230 V
Amperometric protection
Yes
Short circuit protection
Yes
Dry running protection
Yes
Height (cm)
28.2
Width (cm)
23.7
Depth (cm)
18.4
Guarantee
2
Attachments

ACTIVE DRIVER Plus brochure

Overview of the main functionalities and application advantages of ACTIVE DRIVER Plus.

file_download Download (811.47KB)

ACTIVE DRIVER Plus card

Technical and electrical data of all ACTIVE DRIVER Plus models.

file_download Download (1.08MB)

ACTIVE DRIVER PLus manual

Manual of all ACTIVE DRIVER Plus models supplied with the inverter translated into 18 languages.

file_download Download (7.19MB)

ACTIVE DRIVER Plus Guide

Guide with the initial steps for installing the ACTIVE DRIVER Plus.

file_download Download (1.48MB)

Buy it with

  • Active Driver Plus M / T 2.2 - 10.5 A single-phase / three-phase inverter
  • +
  • PWM II 230 1 Basic / 8.5 - 8.5 A single-phase inverter
  • +
  • Sirio XP UNIVERSAL - 14 A single-phase inverter
  • €1,591.00-10 %
    Total price: €1,431.90
Features Active Driver
Scheda inverter

Inverter

The Active Driver Plus makes the pump absorb the minimum power necessary to meet the water needs, avoiding unnecessary waste and allowing significant energy savings.

Display inverter

Display

Highly legible OLED display. The intuitive interface allows you to access all the information and customize the main settings according to the specification.

Aumento della vita della pompa.

Increased pump life.

Thanks to the inverter technology, which reduces the motor speed, there is a considerable increase in the life of the pump.

Predisposizione per il funzionamento nei gruppi

Arrangement for operation in groups

The Active Driver Plus is designed for operation in pressurization groups. Each pump requires an Active Driver Plus that controls it in order to minimize electricity consumption.

Sensori di flusso e di pressione

Flow and pressure sensors

Integrated electronic pressure transducer and flow sensor. The Active Driver Plus does not require external sensors.

Valvola di non ritorno

Non-return valve

Easily removable for maintenance.

MAIN DIFFERENCES WITH THE PREVIOUS MODEL

PREVIOUS MODEL


Modello precedente

NEW PLUS MODEL


Nuovo modello Plus

Reliable

All the experience DAB in mechatronics has been condensed into this product which has been made extremely reliable, powerful and versatile.

Easy to install

All the experience DAB in mechatronics has been condensed into this product which has been made extremely reliable, powerful and versatile.

Easy to set up

The inverter, through the wizard (easily readable on the display), guides the installer to enter all the necessary parameters and in some cases helps in defining the appropriate setting.

Trasparenza e valvola di non ritorno dell'Active Driver Plus

NEW DISPLY AND SOFTWARE INTERFACE

Software

Same functionality as the previous version.

Connectivity with other devices on all models up to 8 pumps.

Backward compatibility of software capable of updating previous versions.

OLED display

Simplified and guided installation through Wizard.

Improved the usability of information thanks to the graphic display.

Better visibility for high resolution and contrast.

Graphic and descriptive explanation of the parameter.

Possibility to choose the language of the menus.

Interface

New 'ENABLE' key to stop / restart the machine.

Interfaccia Active Driver Plus

NEW CONSTRUCTION OF THE COVER

Coperchio Active Driver Plus
  1. Commercial cable glands replace the old molded cable glands offering greater protection.

  2. Added, in the lower part, 3 pre-arranged closed holes for inputs / outputs with M16 plug.

  3. The external tightening screws of the cover and the sealing area increase the sealing reliability of the cover.

OR seat of the cover with better compression and sealing.

Tenuta ACTIVE DRIVER Plus

NEW CONSTRUCTION OF THE BODY

Tappo di scarico dell'Active Driver Plus

3/8 inch plastic drain plug instead of 1/4 inch hex brass.

Sede del sensore dell'Active Driver Plus

Extremely robust pressure sensor seat.

NEW CONSTRUCTION OF THE SINK

  1. Improved cooling of the inverter through the increased water passage hole on the heatsink.



  2. Two models: one for 230 and 1-Basic and one for 400 larger, and internal pocket to help with dissipation.



  3. More accessible coupling screws to the card: these allow the card to be disassembled while keeping the system under pressure.



  4. MatCW617N erial instead of CW614N suitable for drinking water certifications in multiple states.



Dissipatore dell'Active Driver Plus

NEW CONSTRUCTION OF THE ELECTRONIC BOARD

Scheda elettronica dell'Active Driver Plus
  1. Reliability has increased thanks to the switching and non-linear transformer which has also allowed for a reduction in weight.



  2. The cards are unified and all models have 4 Inputs and 2 Outputs.



  3. The 8.5 Arms version now has an available input.



  4. Possibility of installing an auxiliary pressure sensor. For example, it can be installed after a filter (e.g. softener) or a boiler to compensate for their pressure drops.



MANUFACTURING NEWS OF THE NON-RETURN VALVE


Dettaglio valvola di non ritorno dell'Active Driver Plus

Valvola di non ritorno dell'Active Driver Plus
  • Seals on the bushing ensuring greater sealing and lower minimum flow rate.

  • It solves the problem of continuous leaks.

  • Max flow rate 300 l / min guaranteed with pressure drops at 9 meters instead of 15.

  • Special fixing screws from the outside (any leaks do not damage the board).

  • The screws used are of the torx type, with anti-theft pin, with head gasket.

  • Easily maintained thanks to the possibility of replacing the or.

  • Material NORYL.

Related Products