570Z-4P-XF - 10 cm pop-up sprinkler
Turret height 10 centimetres. WITHOUT NOZZLE. With X-Flow device.
The Toro Irrigazione 570Z-4P-XF sprinkler features an X-flow device integrated into the turret that limits water loss by 99% if the nozzle is removed or damaged, eliminating potential erosion or safety issues. Allows "dry" nozzle and filter replacement or maintenance while the system is in operation.
They are characterized by a sealing device that is active even at very low pressures, which allows washing only when the turret is retracted. The 570Z models are ideal for small gardens and green areas.
The check valve (optional) capable of withstanding a difference in height of 3 meters prevents the Pop-Ups positioned at the bottom from continuing to lose water at the end of the irrigation cycle, creating swamps and wasting water.
The XFlow device limits water output by up to a maximum of 2% in the event of tampering.
Patented X-Flow Water Shutoff Device
It is built into the turret and limits water loss by 99% if the nozzle is removed or damaged, thus eliminating concerns about erosion potential or safety. It allows the removal of the nozzle or filter as well as "dry" maintenance, while the system is in operation.
Leak-Free Cleaning Seal
Avoid leaks from the pop-up, allowing multiple sprinklers to be installed on the same line.
Advanced Retraction Spring and Cleaning Seal
Robust recoil spring and improved sealing material ensure excellent turret retraction on all 570Z models.
Integrated check valve
The valve is easily installed in the laboratory or in the field. Maintains up to 3m of height difference.
Small Hat (50 mm.)
Being less visible, it reduces damage from exposure or vandalism.
- Max range (m)
- 5.5
- Tower height (cm.)
- 10
- Attack size
- 1/2 "
- Type of attack
- female
Patented X-Flow device for closing the water
It is built into the turret and limits water loss by 99% should the nozzle be removed or damaged, thus eliminating the concern of potential for erosion or safety. It allows the removal of the nozzle or the filter as well as the "dry" maintenance, while the system is in operation.
Leak-Free Cleaning Gasket
Prevents pop-up leaks by allowing multiple sprinklers to be installed on the same line.
Advanced Retraction Spring and Cleaning Seal
Robust retraction spring and improved sealing material ensure excellent turret retraction on all 570Z models.
Integrated check valve
The valve is easily installed in the laboratory or in the field. Maintains up to 3m of elevation gain.
Small Size Hat (50 mm.)
By being less visible, it reduces damage from exposure or vandalism.