VX 15/50-MF - 1.5 HP three-phase VORTEX electric pump for waste water
Flow rate up to 650 l/min (39 m³/h). Head up to 11 m. 1.1 Kw (1.5 HP) motor.
The VX-MF series pumps are recommended for the drainage of waste water in the domestic, civil and industrial sectors, in all cases where suspended solids are present in the water, for example water mixed with mud, groundwater, surface water.
Its use is recommended for draining flooded areas such as basements, underground car parks, car wash areas, for emptying cesspits and for the disposal of sewage.
The VX-MF pumps are made of micro-cast stainless steel, particularly robust and highly reliable, and offer high performance for professional, chemical and industrial use.
These pumps are distinguished by their reliability, in fixed installations with automatic operation.
- Motor connection
- THREE-PHASE
- Power (HP)
- 1.5
- Absorption at 400V (A)
- 3.0
- Delivery port
- 2"
- Body Pump
- AISI 304 stainless steel
- Impeller
- AISI 304 stainless steel
- Number of impellers
- 1
- Motor shaft
- AISI 304 stainless steel
- Check valve
- no
- Degree of protection
- IP 68
- Flow rate min. (l./min.)
- 50
- Max flow (l./min.)
- 650
- Min head (m.)
- 2
- Max head (m.)
- 11.5
- Employments
- drainage, drying up, slightly dirty waters
- Liquid temperature max. (° C)
- 40
- Height (cm)
- 44.6
- Weight kg)
- 14.5
- Guarantee
- 2
|
|
|
|
|
|
Bearings
Pump side motor bearing | 6303 2RS - C3 |
Opposite side engine bearing | 6203 ZZ |
Tree holding
Type of seal | Double mechanical seal in oil chamber |
LM diameter | 14 |
LM fixed ring | Silicon carbide |
LM rotating ring | Graphite |
LM elastomer | NBR |
Shrinkage DN1=450 DN2=350 | MG1-14D SIC |
LP diameter | 14 |
LP fixed ring | Silicon carbide |
LP rotating ring | Silicon carbide |
LP elastomer | NBR |
Materials
1.0 - Pump body | Stainless steel EN 1.4404 (AISI 316L) |
1.4 - Basic | Stainless steel EN 1.4301 (AISI 304) |
3.0 - Impeller | Stainless steel EN 1.4301 (AISI 304) |
4.0 - Pump shaft | Stainless steel EN 1.4404 (AISI 316L) |
6.0 - Motor holder | Stainless steel EN 1.4301 (AISI 304) |
6.1 - Engine cover | Stainless steel EN 1.4301 (AISI 304) |
7.0 - Lantern | Cast iron GJL 200 EN 1561 |
Compare with Similar Products
VX 15/50-MF - 1.5 HP three-phase VORTEX electric pump for waste waterThis product Flow rate up to 650 l/min (39 m³/h). Head up to 11 m. 1.1 Kw (1.5 HP) motor. | VX 15/35-MF - 1.5 HP three-phase VORTEX electric pump for waste waterFlow rate up to 500 l/min (35 m³/h). Head up to 13.5 m. 1.1 Kw (1.5 HP) motor. | VX 8/50-MF - 0.75 HP three-phase VORTEX electric pump for waste waterFlow rate up to 450 l/min (27 m³/h). Head up to 6 m. 0.55 Kw (0.75 HP) motor. | VX 10/50-MF - 1.5 HP three-phase VORTEX electric pump for waste waterFlow rate up to 550 l/min (33 m³/h). Head up to 8.5 m. 0.75 Kw (1 HP) motor. | |
---|---|---|---|---|
Motor connection | Motor connection THREE-PHASE | Motor connection THREE-PHASE | Motor connection THREE-PHASE | Motor connection THREE-PHASE |
Power (HP) | Power (HP) 1.5 | Power (HP) 1.5 | Power (HP) 0.75 | Power (HP) 1 |
Absorption at 400V (A) | Absorption at 400V (A) 3.0 | Absorption at 400V (A) 3.0 | Absorption at 400V (A) 1.8 | Absorption at 400V (A) 2.0 |
Delivery port | Delivery port 2" | Delivery port 1 "1/2 | Delivery port 2" | Delivery port 2" |
Body Pump | Body Pump AISI 304 stainless steel | Body Pump AISI 304 stainless steel | Body Pump AISI 304 stainless steel | Body Pump AISI 304 stainless steel |
Impeller | Impeller AISI 304 stainless steel | Impeller AISI 304 stainless steel | Impeller AISI 304 stainless steel | Impeller AISI 304 stainless steel |
Number of impellers | Number of impellers 1 | Number of impellers 1 | Number of impellers 1 | Number of impellers 1 |
Motor shaft | Motor shaft AISI 304 stainless steel | Motor shaft AISI 304 stainless steel | Motor shaft AISI 304 stainless steel | Motor shaft AISI 304 stainless steel |
Check valve | Check valve no | Check valve no | Check valve no | Check valve no |
Degree of protection | Degree of protection IP 68 | Degree of protection IP 68 | Degree of protection IP 68 | Degree of protection IP 68 |
Flow rate min. (l./min.) | Flow rate min. (l./min.) 50 | Flow rate min. (l./min.) 50 | Flow rate min. (l./min.) 50 | Flow rate min. (l./min.) 50 |
Max flow (l./min.) | Max flow (l./min.) 650 | Max flow (l./min.) 500 | Max flow (l./min.) 450 | Max flow (l./min.) 550 |
Min head (m.) | Min head (m.) 2 | Min head (m.) 2 | Min head (m.) 1.5 | Min head (m.) 1.5 |
Max head (m.) | Max head (m.) 11.5 | Max head (m.) 14 | Max head (m.) 6.5 | Max head (m.) 9 |
Cable length (m) | Cable length (m) -- | Cable length (m) 10 | Cable length (m) 10 | Cable length (m) 10 |
Employments | Employments drainage, drying up, slightly dirty waters | Employments drainage, drying up, slightly dirty waters | Employments drainage, drying up, slightly dirty waters | Employments drainage, drying up, slightly dirty waters |
Liquid temperature max. (° C) | Liquid temperature max. (° C) 40 | Liquid temperature max. (° C) 40 | Liquid temperature max. (° C) 40 | Liquid temperature max. (° C) 40 |
Height (cm) | Height (cm) 44.6 | Height (cm) 42.1 | Height (cm) 43.1 | Height (cm) 43.1 |
Weight kg) | Weight kg) 14.5 | Weight kg) 14 | Weight kg) 13.1 | Weight kg) 13.1 |
Guarantee | Guarantee 2 | Guarantee 2 | Guarantee 2 | Guarantee 2 |