VX 75/65 - 7.5 HP three-phase VORTEX electric pump for waste water
Flow rate up to 1500 l/min (90 m³/h). Head up to 24 m. 5.5 Kw (7.5 HP) motor.
The VX 75/65 pump built in stainless steel and cast iron of considerable thickness ensures exceptional strength, resistance to abrasion and durability over time.
It is equipped with a VORTEX type impeller, therefore suitable for draining dirty, sewage, waste water, water mixed with mud, revived and putrid sludge.
It is suitable for installation in sewers, tunnels, excavations, canals, underground car parks.
- Motor connection
- THREE-PHASE
- Motor power (HP)
- 7.5
- Absorption at 400V (A)
- 12.7
- Delivery port
- 2"
- Body Pump
- Cast iron
- Impeller
- Cast iron
- Number of impellers
- 1
- Motor shaft
- AISI 431 stainless steel
- Check valve
- no
- Degree of protection
- IP 68
- Flow rate min. (l./min.)
- 200
- Max flow (l./min.)
- 1500
- Min head (m.)
- 5.5
- Max head (m.)
- 24.8
- Cable length (m)
- 10
- Employments
- air conditioning systems, drying up, slightly dirty waters
- Liquid temperature max. (° C)
- +40°C
- Height (cm)
- 70
- Width (cm)
- 27.7
- Weight kg)
- 65
- Guarantee
- 2
|
|
|
|
|
|
Bearings
Pump side motor bearing | 6306 ZZ C3 |
Opposite side engine bearing | 6304 ZZ C3 |
Tree holding
Type of seal | Double Mechanical Seal in tandem with oil chamber |
Engine side model | AR-27 |
LM diameter | 27 |
LM fixed ring | Silicon carbide |
LM rotating ring | Graphite |
LM elastomer | NBR |
Shrinkage DN1=450 DN2=350 | AR-25 |
LP diameter | 25 |
LP fixed ring | Silicon carbide |
LP rotating ring | Silicon carbide |
LP elastomer | NBR |
Materials
1.0 - Pump body | Cast iron GJL 200 EN 1561 |
3.0 - Impeller | Cast iron GJL 200 EN 1561 |
4.0 - Pump shaft | Stainless steel EN 1.4057 (AISI 431) |
6.0 - Motor holder | Stainless steel EN 1.4301 (AISI 304) |
6.1 - Engine cover | Cast iron GJL 200 EN 1561 |
7.0 - Lantern | Cast iron GJL 200 EN 1561 |
Compare with Similar Products
VX 75/65 - 7.5 HP three-phase VORTEX electric pump for waste waterThis product Flow rate up to 1500 l/min (90 m³/h). Head up to 24 m. 5.5 Kw (7.5 HP) motor. | VX 55/50 - 5.5 HP three-phase VORTEX electric pump for waste waterFlow rate up to 1000 l/min (60 m³/h). Head up to 22 m. 4 Kw (5.5 HP) motor. | VX 40/65 - 4 HP three-phase VORTEX electric pump for waste waterFlow rate up to 1200 l/min (72 m³/h). Head up to 16 m. 3 Kw (4 HP) motor. | VX 55/65 - 5.5 HP three-phase VORTEX electric pump for waste waterFlow rate up to 1350 l/min (81 m³/h). Head up to 20 m. 4 Kw (5.5 HP) motor. | |
---|---|---|---|---|
Motor connection | Motor connection THREE-PHASE | Motor connection THREE-PHASE | Motor connection THREE-PHASE | Motor connection THREE-PHASE |
Motor power (HP) | Motor power (HP) 7.5 | Motor power (HP) 5.5 | Motor power (HP) 4 | Motor power (HP) 5.5 |
Absorption at 400V (A) | Absorption at 400V (A) 12.7 | Absorption at 400V (A) 7 | Absorption at 400V (A) 6.2 | Absorption at 400V (A) 7.7 |
Delivery port | Delivery port 2" | Delivery port 2" | Delivery port 2" | Delivery port 2" |
Body Pump | Body Pump Cast iron | Body Pump Cast iron | Body Pump Cast iron | Body Pump Cast iron |
Impeller | Impeller Cast iron | Impeller Cast iron | Impeller Cast iron | Impeller Cast iron |
Number of impellers | Number of impellers 1 | Number of impellers 1 | Number of impellers 1 | Number of impellers 1 |
Motor shaft | Motor shaft AISI 431 stainless steel | Motor shaft AISI 431 stainless steel | Motor shaft AISI 431 stainless steel | Motor shaft AISI 431 stainless steel |
Check valve | Check valve no | Check valve no | Check valve no | Check valve no |
Degree of protection | Degree of protection IP 68 | Degree of protection IP 68 | Degree of protection IP 68 | Degree of protection IP 68 |
Flow rate min. (l./min.) | Flow rate min. (l./min.) 200 | Flow rate min. (l./min.) 100 | Flow rate min. (l./min.) 200 | Flow rate min. (l./min.) 200 |
Max flow (l./min.) | Max flow (l./min.) 1500 | Max flow (l./min.) 1000 | Max flow (l./min.) 1200 | Max flow (l./min.) 1350 |
Min head (m.) | Min head (m.) 5.5 | Min head (m.) 6.5 | Min head (m.) 2.5 | Min head (m.) 3.7 |
Max head (m.) | Max head (m.) 24.8 | Max head (m.) 25 | Max head (m.) 17 | Max head (m.) 20.7 |
Cable length (m) | Cable length (m) 10 | Cable length (m) 10 | Cable length (m) 10 | Cable length (m) 10 |
Employments | Employments air conditioning systems, drying up, slightly dirty waters | Employments air conditioning systems, drying up, slightly dirty waters | Employments air conditioning systems, drying up, slightly dirty waters | Employments air conditioning systems, drying up, slightly dirty waters |
Liquid temperature max. (° C) | Liquid temperature max. (° C) +40°C | Liquid temperature max. (° C) +40°C | Liquid temperature max. (° C) +40°C | Liquid temperature max. (° C) +40°C |
Height (cm) | Height (cm) 70 | Height (cm) 64.2 | Height (cm) 63 | Height (cm) 67 |
Width (cm) | Width (cm) 27.7 | Width (cm) 27.6 | Width (cm) 27.7 | Width (cm) 27.7 |
Weight kg) | Weight kg) 65 | Weight kg) -- | Weight kg) 53.3 | Weight kg) 60 |
Guarantee | Guarantee 2 | Guarantee 2 | Guarantee 2 | Guarantee 2 |