F 65/125A - centrifugal electric Pump of the normalized three-phase
Flow rate up to 2200 l/min (132 m3/h). Head up to 23 m. Motor 7.5 Kw (10 HP).
Used for water supply, washing systems, pressure boosting, fire-fighting installations, irrigation, industry, water circulation in air conditioning systems, and agriculture.
The installation is to be carried out indoors or otherwise protected from the weather.
- Motor connection
- THREE-PHASE
- Power (HP)
- 10
- Absorption at 400V (A)
- 16.5
- Suction mouth
- 3 "
- Delivery port
- 2 "1/2
- Body Pump
- Cast iron
- Impeller
- Cast iron
- Number of impellers
- 1
- Motor shaft
- Stainless steel EN 10088-3 1.4104
- Check valve
- no
- Degree of protection
- IP 55
- Flow rate min. (l./min.)
- 100
- Max flow (l./min.)
- 700
- Min head (m.)
- 41
- Max head (m.)
- 55
- Employments
- water supply, pressurization systems, irrigation, cooling systems, air conditioning systems, washing systems, fire prevention systems
- Liquid temperature max. (° C)
- 90
- Height (cm)
- 34
- Width (cm)
- 55.7
- Weight kg)
- 63.3
- Guarantee
- 2
|
|
|
|
|
Bearings
Pump side motor bearing | 6307 ZZ-C3 |
Opposite side engine bearing | 6206 ZZ-C3 |
Tree holding
Type of seal | Single Mechanical Seal |
Shrinkage DN1=450 DN2=350 | FN-24 |
LP diameter | 24 |
LP fixed ring | Graphite |
LP rotating ring | Ceramic |
LP elastomer | NBR |
Materials
1.0 - Pump body | Cast iron GJL 200 EN 1561 |
2.1 - Seal holder cover | Cast iron GJL 200 EN 1561 |
3.0 - Impeller | Brass CW617N EN 12165 |
4.0 - Pump shaft | Stainless steel EN 1.4057 (AISI 431) |
6.0 - Motor holder | EN-AB 46100 aluminium |
6.1 - Engine cover | EN-AB 46100 aluminium |
7.0 - Lantern | EN-AB 46100 aluminium |
Compare with Similar Products
F 65/125A - centrifugal electric Pump of the normalized three-phaseThis product Flow rate up to 2200 l/min (132 m3/h). Head up to 23 m. Motor 7.5 Kw (10 HP). | F 65/125C - 5.5 HP three-phase standardized centrifugal electric pumpFlow rate up to 1800 l/min (108 m³/h). Head up to 16 m. 4 Kw (5.5 HP) motor. | F 65/125B - centrifugal electric Pump of the normalized three-phaseFlow rates up to 2000 l/min (120 m3/h). Head up to 18 m. Motor 5.5 Kw (7.5 HP). | F 65/160A - 20 HP three-phase standardized centrifugal electric pumpFlow rate up to 2400 l/min (144 m³/h). Head up to 40.5 m. 15 Kw (20 HP) motor. | |
---|---|---|---|---|
Motor connection | Motor connection THREE-PHASE | Motor connection THREE-PHASE | Motor connection THREE-PHASE | Motor connection THREE-PHASE |
Power (HP) | Power (HP) 10 | Power (HP) 5.5 | Power (HP) 7.5 | Power (HP) 20 |
Absorption at 230V (A) | Absorption at 230V (A) -- | Absorption at 230V (A) 17.5 | Absorption at 230V (A) -- | Absorption at 230V (A) -- |
Absorption at 400V (A) | Absorption at 400V (A) 16.5 | Absorption at 400V (A) 10.0 | Absorption at 400V (A) 12.0 | Absorption at 400V (A) 27.5 |
Suction mouth | Suction mouth 3 " | Suction mouth 3 " | Suction mouth 3 " | Suction mouth 3 " |
Delivery port | Delivery port 2 "1/2 | Delivery port 2 "1/2 | Delivery port 2 "1/2 | Delivery port 2 "1/2 |
Body Pump | Body Pump Cast iron | Body Pump Cast iron | Body Pump Cast iron | Body Pump Cast iron |
Impeller | Impeller Cast iron | Impeller Cast iron | Impeller Cast iron | Impeller Cast iron |
Number of impellers | Number of impellers 1 | Number of impellers 1 | Number of impellers 1 | Number of impellers 1 |
Motor shaft | Motor shaft Stainless steel EN 10088-3 1.4104 | Motor shaft Stainless steel EN 10088-3 1.4104 | Motor shaft Stainless steel EN 10088-3 1.4104 | Motor shaft Stainless steel EN 10088-3 1.4104 |
Check valve | Check valve no | Check valve no | Check valve no | Check valve no |
Degree of protection | Degree of protection IP 55 | Degree of protection IP 55 | Degree of protection IP 55 | Degree of protection IP 55 |
Flow rate min. (l./min.) | Flow rate min. (l./min.) 100 | Flow rate min. (l./min.) 100 | Flow rate min. (l./min.) 100 | Flow rate min. (l./min.) 600 |
Max flow (l./min.) | Max flow (l./min.) 700 | Max flow (l./min.) 700 | Max flow (l./min.) 700 | Max flow (l./min.) 2400 |
Min head (m.) | Min head (m.) 41 | Min head (m.) 20 | Min head (m.) 28 | Min head (m.) 28 |
Max head (m.) | Max head (m.) 55 | Max head (m.) 38 | Max head (m.) 47 | Max head (m.) 40.5 |
Employments | Employments water supply, pressurization systems, irrigation, cooling systems, air conditioning systems, washing systems, fire prevention systems | Employments water supply, pressurization systems, irrigation, cooling systems, air conditioning systems, washing systems, fire prevention systems | Employments water supply, pressurization systems, irrigation, cooling systems, air conditioning systems, washing systems, fire prevention systems | Employments water supply, pressurization systems, irrigation, cooling systems, air conditioning systems, washing systems, fire prevention systems |
Liquid temperature max. (° C) | Liquid temperature max. (° C) 90 | Liquid temperature max. (° C) 90 | Liquid temperature max. (° C) 90 | Liquid temperature max. (° C) 90 |
Height (cm) | Height (cm) 34 | Height (cm) 34 | Height (cm) 34 | Height (cm) 36 |
Width (cm) | Width (cm) 55.7 | Width (cm) 51.1 | Width (cm) 55.7 | Width (cm) 71.6 |
Weight kg) | Weight kg) 63.3 | Weight kg) 53.5 | Weight kg) 56.8 | Weight kg) 114.3 |
Guarantee | Guarantee 2 | Guarantee 2 | Guarantee 2 | Guarantee 2 |