GP2W - FCR 80/5 - 2x1 HP three-phase pressure booster set
2 three-phase electric pumps.
2 x 0.75 kW (2 x 1 HP) motor. Flow rate up to 160 l/min (9.6 m³/h). Head up to 67 m.
Delivery Options
| Carrier | Description | Estimated Delivery | |
|---|---|---|---|
![]() | Mail Boxes - 2 giorni | This courier delivers within 48 hours from the moment we entrust the products to him. | Wednesday 5 August - Thursday 6 August |
![]() | Poste Italiane - 2 giorni Italia | This courier delivers within 24/48 hours from the moment we entrust them with the products. | Wednesday 5 August - Thursday 6 August |
![]() | One Express - 2 giorni Italia | This courier delivers within 24/72 hours from the moment we entrust them with the products. | Thursday 6 August - Monday 10 August |
![]() | Poste Italiane - 3 giorni punto di ritiro | This courier delivers within 24/72 hours from the moment we entrust them with the products. | tomorrow |

Carrier: Mail Boxes - 2 giorni
Description: This courier delivers within 48 hours from the moment we entrust the products to him.
Estimated delivery:
Wednesday 5 August - Thursday 6 August

Carrier: Poste Italiane - 2 giorni Italia
Description: This courier delivers within 24/48 hours from the moment we entrust them with the products.
Estimated delivery:
Wednesday 5 August - Thursday 6 August

Carrier: One Express - 2 giorni Italia
Description: This courier delivers within 24/72 hours from the moment we entrust them with the products.
Estimated delivery:
Thursday 6 August - Monday 10 August

Carrier: Poste Italiane - 3 giorni punto di ritiro
Description: This courier delivers within 24/72 hours from the moment we entrust them with the products.
Estimated delivery:
tomorrow




The GP2W - FCR 80/5 pressure group consists of two FCR 80/5 pumps controlled by an MT12 inverter which allows each pump to operate at variable speed and constant pressure.
The type of inverter used, mounted directly on the pump delivery, is dedicated to the control of electric pumps.
The inverter has an internal pressure transducer for maintaining pressure regulation. Flow control therefore stops the pump when there is no water demand from the user, also protecting the pump from depriming in the absence of water.
The unit is supplied with the pressure, absorption and rotation parameters already set, the pressure parameter can be easily changed even after installation.
The operating flow rate is achieved by the simultaneous operation of the two pumps. During periods of low consumption, operation is limited to one pump. Vertical pumps are chosen for their exceptionally quiet operation and high efficiency.
The units are hydraulically and electrically pre-assembled on a frame and include shut-off ball valves with union and ONDASTOP silent diaphragm check valves.
The delivery groups can be combined with a membrane tank, which acts as a water hammer arrester.
Supplied in versions with single-phase 230 volt or three-phase 380 volt power supply.
All our pump units are designed to meet the specific needs of the system, so it is possible to create units with a single pump or with flow rate/head characteristics different from those shown in the table.
- Motor connection
- THREE-PHASE
- Power (Kw)
- 1.5
- Power (HP)
- 2
- Current consumption at 400V (A)
- Suction mouth
- 1" 1/2
- Delivery mouth
- 1" 1/2
- Minimum flow rate (l./min.)
- Max. flow rate (l./min.)
- Min. head (m.)
- Max. head (m.)
- Jobs
- water supply, domestic, pressurization systems, irrigation
- Height (cm)
- Width (cm)
- Depth (cm)
- Weight (Kg)
- Warranty (years)
- 2



